Output: Amplitude Adjustable 0-600 V peak minimum
into 5-ohm non-inductive load at rates of 10 PPS or less.
NOTE: Maximum output voltage will decrease at rates
greater than 10 PPS.
Output Pulse Widths: 10.0 µs, 5.0 µs, 0.15 µs ±20%
into 5-ohm non-inductive load.
NOTE: The polarity of the 0.15 µs pulse is REVERSED
with respect to the 10.0 µs and 5.0 µs pulses.
Amplitude Display: LED Display, accuracy ±5%.
Indicates peak amplitude of output spike as measured into a 5-ohm noninductive load.
Pulse Repetition Rate:
SYNC Mode:
Internal/External: 1-10 PPS
Free Run Mode:
Internal: 0.5-50 PPS
External: >0-50 PPS
Single Pulse Mode: Manually generated, pushbutton.
Pulse Positioning: Positioning range of 1 to 10 PPS pulse is adjustable over 360°
range of power frequencies from 50 to 800 Hz when in SYNC mode.
Electrical Continued
Power Requirements: 115/230 VAC, 50-60 Hz (±10%)
(Factory selectable only)
1.0 A at 115 VAC
0.5 A at 230 VAC
Power Supply:
NOTE: The following voltage/fuse selections are factory selectable only.
Power Requirements:
AC Power Sources:
115 VAC, 50-60 Hz, 1.0 A
230 VAC, 50-60 Hz, 0.5 A
Fuse Specifications:
115 VAC operation: 1.0 A Slow-Blow
230 VAC operation: 0.5 A Slow-Blow
Mechanical
Height: 203 mm (8″) with cover
Width: 229 mm (9″)
127 mm (5″) without cover
Depth: 406 mm (16″)
Weight: 7 kg (15.5 lbs.)